Serial number |
Model |
Component |
Solidify time
(hour/℃) |
Storage period/trial period (month/hour)
|
Heat-resistantgrade |
Use |
1 |
JF-9801B1 |
Single |
4/130 |
6/- |
B |
For common immersed insulation processing B-grade motor, electric appliance and transformer winding. |
2 |
JF-9801B2 |
Double(1:1) |
1.5/130 |
6/720 |
B |
For continuous immersed insulation processing B-grade motor, electric appliance and transformer winding. |
3 |
JF-9801B3 |
Double(1:1) |
0.6-1/130 |
6/36-48 |
B |
For dripping immersed insulation processing B-grade motor, electric appliance and transformer winding. |
4 |
JF-9801F1 |
Single |
4/140 |
6/- |
F |
For common immersed insulation processing B/F-grade motor, electric appliance and transformer winding. |
5 |
JF-9801F2 |
Double(2:1) |
2.5/140 |
6/72 |
F |
For continuous immersed insulation processing B/F-grade motor, electric appliance and transformer winding. |
6 |
JF-9801F3 |
Double(2:1) |
1-1.5/140 |
6/48-72 |
F |
For dripping immersed insulation processing B/F-grade motor, electric appliance and transformer winding. |
7 |
JF-9801F6 |
Single |
4-8/140 |
12/- |
F |
For vacuum pressure insulation processing B/F-grade motor, electric appliance and transformer winding. |
8 |
JF-9801F(6) |
Single |
8-10/150 |
18/- |
F |
For vacuum pressure insulation processing F-grade motor, electric appliance and transformer winding. |
9 |
JF-9801H1 |
Single |
4/160 |
6/- |
H |
For common immersed insulation processing H-grade motor, electric appliance and transformer winding. |
10 |
JF-9801H2 |
Double(4:1) |
1.5-2/140 |
6/360-720 |
H |
For continuous immersed insulation processing B,F/H-grade motor, electric appliance and transformer winding. |
11 |
JF-9801H3 |
Double(4:1) |
1-1.5/150 |
6/72-168 |
H |
For dripping immersed insulation processing F/H-grade motor, electric appliance and transformer winding. |
12 |
JF-9801H6 |
Single |
4-8/140 |
12/- |
H |
For vacuum pressure insulation processing B,F/H-grade motor, electric appliance and transformer winding. |
13 |
JF-9801H(6) |
Single |
10-12/160 |
24/- |
H |
For vacuum pressure insulation processing H-grade motor, electric appliance and transformer winding. |